* Licensed to the Apache Software Foundation (ASF) under one
* or more contributor license agreements. See the NOTICE file
* distributed with this work for additional information
* regarding copyright ownership. The ASF licenses this file
* to you under the Apache License, Version 2.0 (the
* "License"); you may not use this file except in compliance
* with the License. You may obtain a copy of the License at
*
* https://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing,
* software distributed under the License is distributed on an
* "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY
* KIND, either express or implied. See the License for the
* specific language governing permissions and limitations
* under the License.
*/
package org.apache.plc4x.java.spi.connection;
import io.netty.bootstrap.Bootstrap;
import io.netty.channel.Channel;
import io.netty.channel.ChannelFuture;
import io.netty.channel.ChannelHandler;
import io.netty.channel.EventLoopGroup;
import io.netty.channel.nio.NioEventLoopGroup;
import org.apache.plc4x.java.api.exceptions.PlcConnectionException;
import org.slf4j.Logger;
import org.slf4j.LoggerFactory;
import java.net.SocketAddress;
import java.util.Map;
import java.util.concurrent.ConcurrentHashMap;
/**
* Adapter with sensible defaults for a Netty Based Channel Factory.
* <p>
* By Default Nettys {@link NioEventLoopGroup} is used.
* Transports which have to use a different EventLoopGroup have to override {@link #getEventLoopGroup()}.
*/
public abstract class NettyChannelFactory implements ChannelFactory {
private static final Logger logger = LoggerFactory.getLogger(NettyChannelFactory.class);
private final Map<Channel, EventLoopGroup> eventLoops = new ConcurrentHashMap<>();
/**
* TODO should be removed together with the Constructor.
*/
private SocketAddress address;
protected NettyChannelFactory(SocketAddress address) {
this.address = address;
}
/**
* Channel to Use, e.g. NiO, EiO
*/
public abstract Class<? extends Channel> getChannel();
/**
* We need to be able to override this in the TestChanelFactory
*
* @return the Bootstrap instance we will be using to initialize the channel.
*/
protected Bootstrap createBootstrap() {
return new Bootstrap();
}
/**
* This Method is used to modify the Bootstrap Element of Netty, if one wishes to do so.
* E.g. for Protocol Specific extension.
* For TCP e.g.
* <code>
* bootstrap.option(ChannelOption.SO_KEEPALIVE, true);
* bootstrap.option(ChannelOption.TCP_NODELAY, true);
* </code>
*/
public abstract void configureBootstrap(Bootstrap bootstrap);
/**
* Event Loop Group to use.
* Has to be in accordance with {@link #getChannel()}
* otherwise a Runtime Exception will be produced by Netty
* <p>
* By Default Nettys {@link NioEventLoopGroup} is used.
* Transports which have to use a different EventLoopGroup have to override {#getEventLoopGroup()}.
*/
public EventLoopGroup getEventLoopGroup() {
return new NioEventLoopGroup();
}
@Override
public Channel createChannel(ChannelHandler channelHandler) throws PlcConnectionException {
try {
Bootstrap bootstrap = createBootstrap();
EventLoopGroup workerGroup = getEventLoopGroup();
if (workerGroup != null) {
bootstrap.group(workerGroup);
}
bootstrap.channel(getChannel());
// Callback to allow subclasses to modify the Bootstrap
configureBootstrap(bootstrap);
bootstrap.handler(channelHandler);
// Start the client.
final ChannelFuture f = bootstrap.connect(address);
f.addListener(future -> {
if (!future.isSuccess()) {
logger.info("Unable to connect, shutting down worker thread.");
if (workerGroup != null) {
workerGroup.shutdownGracefully();
}
}
});
final Channel channel = f.channel();
if (workerGroup != null) {
// Shut down the workerGroup when channel closing to avoid open too many files
channel.closeFuture().addListener(future -> workerGroup.shutdownGracefully());
// Add to event-loop group
eventLoops.put(channel, workerGroup);
}
// It seems the embedded channel operates differently.
// Intentionally using the class name as we don't want to require a
// hard dependency on the test-channel.
if (!"Plc4xEmbeddedChannel".equals(channel.getClass().getSimpleName())) {
// Wait for sync
f.sync();
// Wait till the session is finished initializing.
f.awaitUninterruptibly(); // jf: unsure if we need that
}
return channel;
} catch (InterruptedException e) {
Thread.currentThread().interrupt();
throw new PlcConnectionException("Error creating channel.", e);
} catch (Throwable t) {
throw new PlcConnectionException("Error creating channel.", t);
}
}
@Override
public void closeEventLoopForChannel(Channel channel) {
if (eventLoops.containsKey(channel)) {
logger.info("Channel is closed, closing worker Group also");
EventLoopGroup eventExecutors = eventLoops.get(channel);
eventLoops.remove(channel);
eventExecutors.shutdownGracefully().awaitUninterruptibly();
logger.info("Worker Group was closed successfully!");
} else {
logger.warn("Trying to remove EventLoop for Channel {} but have none stored", channel);
}
}
}
↑ V6054 Classes should not be compared by their name.